Upgrade MicroOVN across major versions

MicroOVN is released in channels that signify which version of OVN it bundles (e.g. 22.03/stable channel comes with OVN 22.03). These channels track a specific major version, and wont upgrade to next major version on their own. To upgrade to next major version of MicroOVN, you have to change microovn snap channel.

In this how-to, we’ll upgrade a cluster with four members, running MicroOVN 22.03, to MicroOVN 24.03.

Prepare cluster for upgrade

We start by ensuring that each of our cluster members runs MicroOVN from a channel that precedes the version to which we are upgrading, and that it has latest upgrades from this channel.

In this example we are upgrading to 24.03, so we’ll check that our cluster members run 22.03.

snap info microovn

Example of relevant output from snap info:

<snipped preceding output>

snap-id:      llLUDjcLf2hf4zrlty82XqaYTwN4afUP
tracking:     22.03/stable
refresh-date: today at 10:07 UTC

<snipped remaining output>

Next we ensure that MicroOVN runs the latest version in the channel (again on each cluster member):

sudo snap refresh microovn

As a final preparation step, we’ll ensure that all MicroOVN cluster members are online by running:

sudo microovn cluster list -f compact

It’s sufficient to run this command on a single member. Resulting output should show status of all members as ONLINE:

NAME        ADDRESS          ROLE                              FINGERPRINT                             STATUS
movn1  10.75.224.44:6443   voter     0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683  ONLINE
movn2  10.75.224.233:6443  stand-by  b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981  ONLINE
movn3  10.75.224.128:6443  voter     fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a  ONLINE
movn4  10.75.224.11:6443   voter     fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b  ONLINE

Ensure sufficient election timer

Upgrade of OVN cluster can be computationally stressful operation, especially for nodes that run OVN central services. To prevent cluster members from missing heartbeats and causing leadership flapping, we recommend setting election timer of Northbound and Southbound databases to at least 16 seconds.

To check current values, run following commands:

# Get OVN Northbound cluster status
sudo microovn.ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnnb_db.ctl cluster/status OVN_Northbound

# Get OVN Southbound cluster status
sudo microovn.ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnsb_db.ctl cluster/status OVN_Southbound

Look for Election timer: in the output of these commands. Value of this field is expressed in milliseconds.

<snipped preceding output>

Last Election won: 56593 ms ago
Election timer: 16000
Log: [2, 8]
Entries not yet committed: 0
Entries not yet applied: 0
Connections:
Disconnections: 0

<snipped remaining output>

If the value is lower than 16000, we recommend gradually increasing it with:

# Command example for Northbound election timer increase
microovn.ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnnb_db.ctl cluster/change-election-timer OVN_Northbound <new_value>

# Command example for Southbound election timer increase
microovn.ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnsb_db.ctl cluster/change-election-timer OVN_Southbound <new_value>

OVN wont let you increase the timer by more than twice its current value, so you will have to proceed gradually.

Upgrade single cluster member

Now we can proceed with upgrade of individual members in the cluster. The process itself is very straightforward, we just need to keep an eye on it, to ensure that it finishes as expected.

We’ll start by upgrading single cluster member by running following command on it:

sudo snap refresh --channel=24.03/stable microovn

Important

Above command causes restart of MicroOVN and OVN services running on this cluster member. This results in temporary data plane outage, for ports connected to OVN Chassis located on this member, while services come back up and reconfigure datapaths.

After the snap is successfully upgraded, there may be changes to either the dqlite schema or the ovsdb schema, or both. We can check the cluster status with:

sudo microovn cluster list -f compact

Systems that report UPGRADING have encountered a dqlite schema update and are awaiting all cluster members to receive the update. The systems that report NEEDS UPGRADE have not yet received the update and continue to function as before. Any systems that are UPGRADING will be unreachable by these systems.

NAME        ADDRESS          ROLE                              FINGERPRINT                                STATUS
movn1  10.75.224.44:6443   voter     0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683  UPGRADING
movn2  10.75.224.233:6443  stand-by  b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981  NEEDS UPGRADE
movn3  10.75.224.128:6443  voter     fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a  NEEDS UPGRADE
movn4  10.75.224.11:6443   voter     fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b  NEEDS UPGRADE

After all systems are refreshed, they should report ONLINE once again:

NAME        ADDRESS          ROLE                              FINGERPRINT                             STATUS
movn1  10.75.224.44:6443   voter     0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683  ONLINE
movn2  10.75.224.233:6443  stand-by  b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981  ONLINE
movn3  10.75.224.128:6443  voter     fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a  ONLINE
movn4  10.75.224.11:6443   voter     fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b  ONLINE

If there was no dqlite schema update, there may still be an ovsdb schema update. In this case the systems may report ONLINE as soon as the first system is refreshed. The cluster status can be viewed with:

sudo microovn status

The output of the command above will look something like this:

<snipped preceding output>

OVN Database summary:
OVN Southbound: Upgrade or attention required!
Currently running schema: 20.21.0
Cluster report (expected schema versions):
        movn1: 20.33.0
    movn4: Missing API. MicroOVN needs upgrade
    movn2: Missing API. MicroOVN needs upgrade
    movn3: Missing API. MicroOVN needs upgrade

OVN Northbound: Upgrade or attention required!
Currently running schema: 6.1.0
Cluster report (expected schema versions):
    movn1: 7.3.0
    movn4: Missing API. MicroOVN needs upgrade
    movn3: Missing API. MicroOVN needs upgrade
    movn2: Missing API. MicroOVN needs upgrade

We can see, from the output above, that host movn1, as the only upgraded member so far, reports that it expects different OVN Southbound and OVN Northbound database schema version, as the cluster is currently running. This is expected and it will remain the case until all the cluster members are upgraded, at which point the schema upgrade will be triggered.

Note

As the MicroOVN version 24.03 is first to support API required to report expected schema versions, you will see placeholder messages Missing API. MicroOVN needs upgrade coming from hosts that run older MicroOVN versions. Going forward, the output during the future upgrades would look something like this:

OVN Northbound: Upgrade or attention required!
Currently running schema: 6.1.0
Cluster report (expected schema versions):
    movn1: 7.3.0
    movn4: 6.1.0
    movn3: 6.1.0
    movn2: 6.1.0

Note

If you run microovn status immediately after the snap refresh, you may encounter following, or similar, error messages in the output:

OVN Database summary:
Failed to fetch OVN Southbound schema status: failed to fetch OVN Southbound cluster schema status from 'http://control.socket': Internal Server Error
Error: failed to fetch either Southbound or Northbound database status

It is expected, as it takes few seconds for the member to reconnect back to the cluster. The error message should go away after few seconds.

If you run microovn status and you encounter the following error, it means there is also a dqlite schema update, which can be viewed with sudo microovn cluster list:

Failed listing services: Database is waiting for an upgrade. 3 cluster members have not yet received the update

Continue with cluster upgrade

Same commands, from the previous section, can be run on the rest of the cluster members. You should progress one cluster member at a time and check the output of microovn cluster status to see if the upgrade continues as expected.

Final verification

After the last cluster member is upgraded, MicroOVN will trigger schema upgrade of OVN databases. This is an asynchronous process that can take from few seconds, to few minutes, depending on the size of the database. You can run:

sudo microovn status

and if the schema upgrade finished successfully, you’ll see following output:

<snipped preceding output>

OVN Database summary:
OVN Southbound: OK (20.33.0)
OVN Northbound: OK (7.3.0)