Upgrade MicroOVN across major versions¶
MicroOVN is released in channels that signify which version of OVN
it
bundles (e.g. 22.03/stable
channel comes with OVN 22.03
). These
channels track a specific major version, and wont upgrade to next major
version on their own. To upgrade to next major version of MicroOVN, you have
to change microovn
snap channel.
In this how-to, we’ll upgrade a cluster with four members, running
MicroOVN 22.03
, to MicroOVN 24.03
.
Prepare cluster for upgrade¶
We start by ensuring that each of our cluster members runs MicroOVN from a channel that precedes the version to which we are upgrading, and that it has latest upgrades from this channel.
In this example we are upgrading to 24.03
, so we’ll check that our cluster
members run 22.03
.
snap info microovn
Example of relevant output from snap info
:
<snipped preceding output>
snap-id: llLUDjcLf2hf4zrlty82XqaYTwN4afUP
tracking: 22.03/stable
refresh-date: today at 10:07 UTC
<snipped remaining output>
Next we ensure that MicroOVN runs the latest version in the channel (again on each cluster member):
sudo snap refresh microovn
As a final preparation step, we’ll ensure that all MicroOVN cluster members are online by running:
sudo microovn cluster list -f compact
It’s sufficient to run this command on a single member. Resulting output
should show status of all members as ONLINE
:
NAME ADDRESS ROLE FINGERPRINT STATUS
movn1 10.75.224.44:6443 voter 0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683 ONLINE
movn2 10.75.224.233:6443 stand-by b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981 ONLINE
movn3 10.75.224.128:6443 voter fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a ONLINE
movn4 10.75.224.11:6443 voter fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b ONLINE
Ensure sufficient election timer¶
Upgrade of OVN cluster can be computationally stressful operation, especially
for nodes that run OVN central
services. To prevent cluster members from
missing heartbeats and causing leadership flapping, we recommend setting
election timer
of Northbound
and Southbound
databases to at least
16 seconds
.
To check current values, run following commands:
# Get OVN Northbound cluster status
sudo ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnnb_db.ctl cluster/status OVN_Northbound
# Get OVN Southbound cluster status
sudo ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnsb_db.ctl cluster/status OVN_Southbound
Look for Election timer:
in the output of these commands. Value of this
field is expressed in milliseconds.
<snipped preceding output>
Last Election won: 56593 ms ago
Election timer: 16000
Log: [2, 8]
Entries not yet committed: 0
Entries not yet applied: 0
Connections:
Disconnections: 0
<snipped remaining output>
If the value is lower than 16000
, we recommend gradually increasing it
with:
# Command example for Northbound election timer increase
ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnnb_db.ctl cluster/change-election-timer OVN_Northbound <new_value>
# Command example for Southbound election timer increase
ovn-appctl -t /var/snap/microovn/common/run/ovn/ovnsb_db.ctl cluster/change-election-timer OVN_Southbound <new_value>
OVN
wont let you increase the timer by more than twice its current
value, so you will have to proceed gradually.
Upgrade single cluster member¶
Now we can proceed with upgrade of individual members in the cluster. The process itself is very straightforward, we just need to keep an eye on it, to ensure that it finishes as expected.
We’ll start by upgrading single cluster member by running following command on it:
sudo snap refresh --channel=24.03/stable microovn
Important
Above command causes restart of MicroOVN and OVN services running on this cluster member. This results in temporary data plane outage, for ports connected to OVN Chassis located on this member, while services come back up and reconfigure datapaths.
After the snap is successfully upgraded, there may be changes to either the dqlite
schema or the ovsdb
schema, or both.
We can check the cluster status with:
sudo microovn cluster list -f compact
Systems that report UPGRADING
have encountered a dqlite
schema update and are awaiting all cluster members to receive the update.
The systems that report NEEDS UPGRADE
have not yet received the update and continue to function as before. Any systems that are UPGRADING
will be unreachable by these systems.
NAME ADDRESS ROLE FINGERPRINT STATUS
movn1 10.75.224.44:6443 voter 0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683 UPGRADING
movn2 10.75.224.233:6443 stand-by b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981 NEEDS UPGRADE
movn3 10.75.224.128:6443 voter fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a NEEDS UPGRADE
movn4 10.75.224.11:6443 voter fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b NEEDS UPGRADE
After all systems are refreshed, they should report ONLINE
once again:
NAME ADDRESS ROLE FINGERPRINT STATUS
movn1 10.75.224.44:6443 voter 0e359bed39fb0aaedcb730c707b89701abfb0a65ed5e0f9b5ff883a75c914683 ONLINE
movn2 10.75.224.233:6443 stand-by b084c2fadd4ca66ffd8fb7e58a1f90f2bbec1fec5ec6d4091eba7e7fbbb66981 ONLINE
movn3 10.75.224.128:6443 voter fc9efe07194030ec212a75d32e525a321eb973a0cf071c2bc8841480457a248a ONLINE
movn4 10.75.224.11:6443 voter fa3380a109f48e5bce60ba942cf24617d5db3b4f371dedc6ef732303ada7ed0b ONLINE
If there was no dqlite
schema update, there may still be an ovsdb
schema update.
In this case the systems may report ONLINE
as soon as the first system is refreshed.
The cluster status can be viewed with:
sudo microovn status
The output of the command above will look something like this:
<snipped preceding output>
OVN Database summary:
OVN Southbound: Upgrade or attention required!
Currently running schema: 20.21.0
Cluster report (expected schema versions):
movn1: 20.33.0
movn4: Missing API. MicroOVN needs upgrade
movn2: Missing API. MicroOVN needs upgrade
movn3: Missing API. MicroOVN needs upgrade
OVN Northbound: Upgrade or attention required!
Currently running schema: 6.1.0
Cluster report (expected schema versions):
movn1: 7.3.0
movn4: Missing API. MicroOVN needs upgrade
movn3: Missing API. MicroOVN needs upgrade
movn2: Missing API. MicroOVN needs upgrade
We can see, from the output above, that host movn1
, as the only
upgraded member so far, reports that it expects different OVN Southbound
and OVN Northbound
database schema version, as the cluster is currently
running. This is expected and it will remain the case until all the cluster
members are upgraded, at which point the schema upgrade will be triggered.
Note
As the MicroOVN version 24.03
is first to support API required to
report expected schema versions, you will see placeholder messages
Missing API. MicroOVN needs upgrade
coming from hosts that run
older MicroOVN versions. Going forward, the output during the future
upgrades would look something like this:
OVN Northbound: Upgrade or attention required!
Currently running schema: 6.1.0
Cluster report (expected schema versions):
movn1: 7.3.0
movn4: 6.1.0
movn3: 6.1.0
movn2: 6.1.0
Note
If you run microovn status
immediately after the snap refresh, you
may encounter following, or similar, error messages in the output:
OVN Database summary:
Failed to fetch OVN Southbound schema status: failed to fetch OVN Southbound cluster schema status from 'http://control.socket': Internal Server Error
Error: failed to fetch either Southbound or Northbound database status
It is expected, as it takes few seconds for the member to reconnect back to the cluster. The error message should go away after few seconds.
If you run microovn status
and you encounter the following error, it means there is also a dqlite
schema update, which can be viewed with sudo microovn cluster list
:
Failed listing services: Database is waiting for an upgrade. 3 cluster members have not yet received the update
Continue with cluster upgrade¶
Same commands, from the previous section, can be run on the rest of
the cluster members. You should progress one cluster member at a time
and check the output of microovn cluster status
to see if the upgrade
continues as expected.
Final verification¶
After the last cluster member is upgraded, MicroOVN will trigger schema upgrade of OVN databases. This is an asynchronous process that can take from few seconds, to few minutes, depending on the size of the database. You can run:
sudo microovn status
and if the schema upgrade finished successfully, you’ll see following output:
<snipped preceding output>
OVN Database summary:
OVN Southbound: OK (20.33.0)
OVN Northbound: OK (7.3.0)